{"product_id":"jackson-rackstar-44-high-temp-conveyor-dishwasher-224-racks","title":"Jackson RackStar 44 High Temperature Conveyor Dishwasher, Electric or Steam, 224 Racks\/Hr","description":"\u003ch3\u003eWhy Jackson RackStar 44 Conveyor Dishwasher?\u003c\/h3\u003e\n\u003cp\u003eThe Jackson RackStar 44 is a 44 in. high temperature sanitizing conveyor dishwasher that cleans 224 racks per hour on as little as 0.38 gallons of water per rack. The WISR cleaning system, self-cleaning wash arms and Dual Rainbow Rinse give one-pass cleaning, and EnergyGuard controls and an idle vent fan shutoff cut utility use. Choose the 44CE with electric tank heat and a built-in 70°F rise booster, which is ENERGY STAR certified, or the 44CS with steam tank heat. Perfection Plaza supplies the RackStar line to restaurants, hospitals and institutional kitchens.\u003c\/p\u003e\n\u003ch3\u003ePerformance \u0026amp; Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo heat options:\u003c\/strong\u003e CE models use electric tank heat with a built-in 24 kW, 70°F (38.9°C) rise booster; CS models use steam tank heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWISR cleaning system:\u003c\/strong\u003e Jackson's WISR cleaning system with self-cleaning wash arms gives one-pass cleaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Rainbow Rinse:\u003c\/strong\u003e Arched Rainbow Rinse arms with an adjustable rinse: Econo 0.38 gallons per rack or Turbo 0.65 gallons per rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThroughput:\u003c\/strong\u003e 224 racks per hour (5,600 dishes or 8,064 glasses) at a conveyor speed of 6.10 ft\/min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergyGuard controls:\u003c\/strong\u003e Exclusive EnergyGuard controls, plus vent fan control that shuts the vent fan off when the machine is idle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Automatic tank fill, digital LED display and a delime cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChamber clearance:\u003c\/strong\u003e 19-3\/4 in. (502 mm) vertical chamber clearance standard; higher than standard chamber height optional (25 in. with high hood).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrike plate table limit switch:\u003c\/strong\u003e Included as standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuild Quality \u0026amp; Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged doors:\u003c\/strong\u003e Large front access for cleaning and maintenance; double-wall insulated doors retain heat, keeping wash water hot and the dishroom cooler.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel construction:\u003c\/strong\u003e Durable stainless steel construction with a stainless steel front dress panel, strainer pans and splash shields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-draining wash pump:\u003c\/strong\u003e Stainless steel, 3.0 HP, 270 GPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable vent cowl collars:\u003c\/strong\u003e Help fit the machine to the exhaust system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eJackson WWS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eRackStar 44CE (electric tank heat, 24 kW\/70°F rise onboard booster); RackStar 44CS (steam tank heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMachine Type\u003c\/th\u003e\n\u003ctd\u003e44 in. high temperature sanitizing conveyor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRacks per Hour\u003c\/th\u003e\n\u003ctd\u003e224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDishes per Hour\u003c\/th\u003e\n\u003ctd\u003e5,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlasses per Hour\u003c\/th\u003e\n\u003ctd\u003e8,064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConveyor Speed\u003c\/th\u003e\n\u003ctd\u003e6.10 ft\/min (1.86 MPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWash Temperature (minimum)\u003c\/th\u003e\n\u003ctd\u003e160°F (71°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRinse Temperature (minimum)\u003c\/th\u003e\n\u003ctd\u003e180°F (82°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater per Rack\u003c\/th\u003e\n\u003ctd\u003eEcono rinse 0.38 gal (1.4 L); Turbo rinse 0.65 gal (2.5 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater per Hour\u003c\/th\u003e\n\u003ctd\u003eEcono 85.12 gal (322.2 L); Turbo 145.60 gal (551.2 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Rate\u003c\/th\u003e\n\u003ctd\u003e1.30 GPM (4.9 LPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWash Tank Capacity\u003c\/th\u003e\n\u003ctd\u003e70°F rise booster (standard): 24.00 gal (90.8 L); no booster: 27.21 gal (103.0 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWash Pump Capacity\u003c\/th\u003e\n\u003ctd\u003e270 GPM (1,022 LPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncoming Water Temperature\u003c\/th\u003e\n\u003ctd\u003e70°F rise booster: 110°F (43°C); no booster: 180°F (82°C); steam models: 180°F minimum supplied from steam booster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Pressure\u003c\/th\u003e\n\u003ctd\u003e20 ± 2 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater Inlet (NPT)\u003c\/th\u003e\n\u003ctd\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrain Connection (NPT)\u003c\/th\u003e\n\u003ctd\u003e1-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWash Pump Motor\u003c\/th\u003e\n\u003ctd\u003e3.0 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrive Motor\u003c\/th\u003e\n\u003ctd\u003e1\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWash Tank Heater\u003c\/th\u003e\n\u003ctd\u003e15.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRinse Tank Heater (booster)\u003c\/th\u003e\n\u003ctd\u003e24.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSteam (CS models)\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. NPT connection; 10-30 PSI flow pressure; 60 lbs\/hr consumption at 15 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eInput end 200 CFM; output end 200 CFM; total 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, 44CE with 24 kW booster, 208\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 118.6 A; min. circuit ampacity 120.9 A; max. overcurrent protection 130.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, 44CE with 24 kW booster, 230\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 99.6 A; min. circuit ampacity 101.8 A; max. overcurrent protection 110.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, 44CE with 24 kW booster, 460\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 50.0 A; min. circuit ampacity 51.1 A; max. overcurrent protection 55.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, electric with no booster, 208\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 51.9 A; min. circuit ampacity 54.2 A; max. overcurrent protection 60.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, electric with no booster, 230\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 44.3 A; min. circuit ampacity 46.4 A; max. overcurrent protection 55.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle point, electric with no booster, 460\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 22.3 A; min. circuit ampacity 23.4 A; max. overcurrent protection 25.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e44CS steam tank heat, 208\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 10.3 A; min. circuit ampacity 12.6 A; max. overcurrent protection 20.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e44CS steam tank heat, 230\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 9.7 A; min. circuit ampacity 11.9 A; max. overcurrent protection 20.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e44CS steam tank heat, 460\/60\/3\u003c\/th\u003e\n\u003ctd\u003eTotal load 5.0 A; min. circuit ampacity 6.1 A; max. overcurrent protection 15.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDual point, 208\/60\/3\u003c\/th\u003e\n\u003ctd\u003eUnit 51.9 A \/ 54.2 A MCA \/ 60.0 A MOP; booster 66.6 \/ 67.9 \/ 70.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDual point, 230\/60\/3\u003c\/th\u003e\n\u003ctd\u003eUnit 44.3 \/ 46.4 \/ 50.0 A; booster 55.3 \/ 56.6 \/ 60.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDual point, 460\/60\/3\u003c\/th\u003e\n\u003ctd\u003eUnit 22.3 \/ 23.4 \/ 25.0 A; booster 27.7 \/ 29.0 \/ 30.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e64 in. (1626 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth between Tables\u003c\/th\u003e\n\u003ctd\u003e44 in. (1118 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e30 in. (762 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth with Door Open\u003c\/th\u003e\n\u003ctd\u003e50 in. (1270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003eStandard 68-1\/2 in. (1740 mm); high hood 73-3\/4 in. (1873 mm); can be increased 1-3\/4 in. with adjustable feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInside Clearance Height\u003c\/th\u003e\n\u003ctd\u003eStandard 19-3\/4 in. (502 mm); high hood 25 in. (635 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWall Clearance\u003c\/th\u003e\n\u003ctd\u003e4 in. (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrain Height\u003c\/th\u003e\n\u003ctd\u003e6-7\/8 in. (175 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003eStandard 727 lbs (330 kg); high hood 737 lbs (334 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003eStandard 802 lbs; high hood 812 lbs (368 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e76 in. W x 40 in. D x 75 in. H (1930 x 1016 x 1905 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping Cube \/ Class\u003c\/th\u003e\n\u003ctd\u003e131.94 cu ft \/ Class 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e3-phase only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eENERGY STAR (electric models with booster); cETLus; ETL Sanitation listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year parts and labor warranty (as stated by Jackson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater Heater Advisory\u003c\/th\u003e\n\u003ctd\u003eJackson does not endorse tankless on-demand water heaters for its dishmachines and recommends a standard tank-style water heater sized for the facility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eResources\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/jackson-wws.dcatalog.com\/v\/RackStar-44-Spec-Sheet\/\" target=\"_blank\"\u003e RackStar 44 Specification Sheet View Online \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/jackson-wws.dcatalog.com\/v\/RackStar-Side-Loader-Spec-Sheet\/\" target=\"_blank\"\u003e RackStar Sideloader Specification Sheet View Online \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-Onboard-Hatco-Boosters-Installation-and-Operation-Guide.pdf\" target=\"_blank\"\u003e Onboard Hatco Boosters Installation and Operation Guide Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-RackStar-3-Manual.pdf\" target=\"_blank\"\u003e RackStar 3 Manual Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-RackStar-Install-Guide.pdf\" target=\"_blank\"\u003e RackStar Install Guide Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-RackStar-Manual.pdf\" target=\"_blank\"\u003e RackStar Manual Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-RackStar-Operation-Guide.pdf\" target=\"_blank\"\u003e RackStar Operation Guide Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-RackStar-Security-Addendum.pdf\" target=\"_blank\"\u003e RackStar Security Package Addendum Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-J-120-Technical-Manual.pdf\" target=\"_blank\"\u003e Steam Booster Manual Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noreferrer noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/jackson-wws-JWWS-Limited-Warranty.pdf\" target=\"_blank\"\u003e Jackson WWS Manufacturer’s Limited Warranty Download PDF \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jackson WWS","offers":[{"title":"RackStar 44CE","offer_id":66852606247027,"sku":"RackStar 44CE","price":32312.0,"currency_code":"USD","in_stock":true},{"title":"RackStar 44CS","offer_id":66852606279795,"sku":"RackStar 44CS","price":30251.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/6406\/2835\/files\/RackStar-44-e1741371084471.jpg?v=1791865969","url":"https:\/\/perfectionplaza.com\/products\/jackson-rackstar-44-high-temp-conveyor-dishwasher-224-racks","provider":"Perfection Plaza LLC","version":"1.0","type":"link"}